Why is it difficult to switch large-diameter valves? How to solve the problem?

Editor:嘉興美克斯閥門有限公司 │ Release Time:2022-01-12 

Among users who use large-diameter globe valves on a daily basis, they often report a problem that large-diameter globe valves are often difficult to close when they are used in media with a relatively large pressure difference, such as steam, high-pressure water, etc. When closing with force, it is always found that there will be leakage, and it is difficult to close tightly. The reason for this problem is caused by the structural design of the valve and the insufficient output torque of the human limit level.


Analysis of the Difficulty in Switching Large Diameter Valves


The average adult's horizontal limit output force is 60-90kg, depending on different physiques.


Generally, the flow direction of the globe valve is designed to be low in and high out. When a person closes the valve, the human body pushes the handwheel to rotate horizontally, so that the valve flap moves downward to realize the closing. At this time, it is necessary to overcome the combination of three forces, namely :


1) Axial thrust force Fa;


2) Friction force Fb between packing and valve stem;


3) The friction force Fc between the valve stem and the valve disc core


The sum of moments is ∑M=(Fa+Fb+Fc)R


It can be seen that the larger the diameter, the greater the axial thrust force. When it is close to the closed state, the axial thrust force is almost close to the actual pressure of the pipe network (because when it is closed, P1-P2≈P1, P2=0)


For example, a DN200 caliber globe valve is used on a 10bar steam pipe, only the first closing axial thrust Fa=10×πr2=3140kg, and the horizontal circular force required for closing is close to the horizontal circular force that normal human bodies can output. force limit, so it is very difficult for one person to fully close the valve under this condition.


Of course, some factories recommend installing such valves in reverse, which solves the problem of being difficult to close, but there is also the problem that it is difficult to open after closing.


Analysis of the Causes of Internal Leakage of Large Diameter Globe Valves


Large-diameter globe valves are generally used in boiler outlet, main cylinder, steam main and other positions. These positions have the following problems:


1) Generally, the pressure difference at the boiler outlet is relatively large, so the steam flow rate is also larger, and the erosion damage to the sealing surface is also larger. In addition, the combustion efficiency of the boiler cannot be 100%, which will cause the steam at the outlet of the boiler to have a large water content, which will easily cause cavitation and cavitation damage to the valve sealing surface.


2) For the shut-off valve near the boiler outlet and the sub-cylinder, because the steam that has just come out of the boiler has intermittent superheating phenomenon, in the process of its saturation, if the softening treatment of the boiler water is not very good, part of the acid is often precipitated Alkali substances will cause corrosion and erosion to the sealing surface; some crystallizable substances may also adhere to the valve sealing surface and crystallize, resulting in the valve not being able to be tightly sealed.


3) For the inlet and outlet valves of the sub-cylinders, the steam consumption after the valve is large and sometimes small due to production requirements and other reasons. The valve sealing surface causes erosion, cavitation and other damage.


4) Generally, when a large-diameter pipeline is opened, the pipeline needs to be preheated, and the preheating process generally requires a small flow of steam to pass through, so that the pipeline can be heated slowly and evenly to a certain extent before the stop valve can be fully opened to avoid causing the pipeline to rapidly Excessive expansion caused by heating up and damage to some connection parts. However, in this process, the valve opening is often very small, which causes the erosion rate to be far greater than the normal use effect, and seriously reduces the service life of the valve sealing surface.


Solutions to Difficulties in Switching Large Diameter Globe Valves


1) First of all, it is recommended to choose a bellows-sealed globe valve, which avoids the influence of the frictional resistance of the plunger valve and the packing valve, and makes the switch easier.


2) The valve core and seat must be made of materials with good erosion resistance and wear resistance, such as Stellite carbide.


3) It is recommended to adopt a double valve disc structure, which will not cause excessive erosion due to the small opening, which will affect the service life and sealing effect.


主站蜘蛛池模板: 免费人妻无码不卡中文字幕18禁 | 中文字幕一区二区三区在线视频 | 亚洲第一精品夜夜躁人人爽 | 欧美国产亚洲精品久久久8v | 欧美亚洲国产成人一区二区三区 | 精品亚洲成a人在线观看 | 亚洲成A人V欧美综合天堂麻豆 | 色综合色欲色综合色综合色乛 | 超爱碰在线资源 | 国产无遮挡乱子伦免费精品 | 欧美激情一区二区三区AA片 | 久久精品6 | japanese在线看 | 国产熟女精品视 | 97久人人做人人妻人人玩精品 | 成人福利视频在线观看 | 亚洲国产精品成人精品无码区 | 日日夜夜噜 | 91热精品视频 | AV无码久久久久不卡免费网站 | 久久精品国产亚洲AV忘忧草18 | аⅴ资源中文在线天堂 | 国产婷婷综合在线视频中文 | av资源站最稳定的资源站 | 少妇被又粗又里进进出出 | 日本理论大片 | 美女视频免费是黄的网站高清 | 人间精品视频在线播放 | 这里只有精品在线播放 | 公车高h | 久久性av | 人妻无码一区二区视频 | 春意午夜影院 | 国产精品人妖ts系列视频 | 天天干夜夜操 | 黄色的毛片 | 久久精品2021国产 | 中文字幕亚洲码在线观看 | 免费观看丰满少妇做爰 | 四虎成人精品永久免费av | 午夜精品久久17c |